Place of Origin: | CHINA |
Brand Name: | SKYLINE |
Certification: | CE , Calibration Certificate |
Model Number: | SL-OA89 |
Minimum Order Quantity: | 1 Unit |
---|---|
Price: | negotiated |
Packaging Details: | plywood case |
Delivery Time: | 15 working days |
Payment Terms: | L/C, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10 unit / month |
Operating Temperature: | 80 ~ -40℃ | Temperature Control Accuracy: | ±0.02℃ |
---|---|---|---|
Working Hole: | 9 Holes | Temperature Control Mode: | Program Temperature Control |
Heating Method: | Electric Heat Pipe Heating | Detection Method: | Photocell Detection |
Refrigeration Mode: | Imported Compressor Cooling | Control Mode: | Computer Automatic Control |
Highlight: | astm d 4684 mini rotary viscometer,9 holes mini rotary viscometer |
1.10.1 inch true color TFT-LCD LCD display; The keyboard uses a human sensing touch screen. English operation interface, clear display, easy control, touch freely.
2. Instrument configuration of automatic diagnosis system, automatic fault prompt function.
3. The instrument uses imported photoelectric detection switch to detect rotor speed, with photoelectric encoder test function.
4. The instrument adopts intelligent operating system, users only need to click the operation, the instrument automatically control temperature, automatic timing, automatic speed measurement, automatic calculation.
5. The instrument adopts imported compressor refrigeration, refrigeration capacity is sufficient, cold bath temperature stability is good, instead of the traditional semiconductor refrigeration because of the long experimental time needs a large number of circulating water drawbacks.
6. The printer adopts micro embedded thermal printer, printing more quiet, fast, clear; Can also be customized needle printer, printing results for a long time do not fade.
7. Historical data storage using FLASH data storage, can store 2010 historical data, data can be stored for 10 years without loss, stored data cannot be changed.
Operating temperature: | 80 ~ -40℃ |
Temperature control accuracy | ±0.02℃ |
Working hole | 9 holes |
Temperature control mode | program temperature control |
Heating method | Electric heat pipe heating |
Detection method | Photocell detection |
Refrigeration mode | Imported compressor cooling |
Control mode | Computer automatic control |
Power supply voltage | 220±10% V.AC |
Power frequency | 50±10% Hz |
Power | 2300KW |
Instrument size | Host 470*320*420mm |
Cold bath | 470 * 4000 * 560 mm |
Net weight | about 80Kg |
Contact Person: Ms. Ivy Xie
Tel: 86-13751491529
Fax: 86-769-38818154
ISO 5660 AC220V Cone Calorimeter For Building Materials Testing
Fire Testing Equipment Steiner Tunnel Test Apparatus
BIFMA 5.1 Furniture Testing Equipment Chair Seat Impact Testing Machine
SL-TL01 Luggage Walking Bump Test Machine/ Running Machine / Castor Test Machine
IS5967 Strength Testing Equipment , Stability Testing Equipment For Tables And Trolleys